Scientific Reports volume 12, Article number: 18088 (2022) Cite this article
632 Accesses
1 Citations
Metrics details
Of crucial importance for giant magnetostrictive transducers (GMTs) design is to quickly and accurately analysis the temperature distribution. With the advantages of low calculation cost and high accuracy, thermal network modelling has been developed for thermal analysis of GMT. However, the existing thermal models have their limits to describe these complicated thermal behaviors in the GMTs: most of researches focused on steady-state which is incapable of capturing temperature variances; the temperature distribution of giant magnetostrictive (GMM) rods is generally assumed to be uniform whereas the temperature gradient on the GMM rod is remarkable due to its poor thermal conductivity; the non-uniform distribution of GMM's losses is seldom introduced into thermal model. Therefore, a transient equivalent thermal network (TETN) model of GMT is established in this paper, considering the aforementioned three aspects. Firstly, based on the structure and working principle of a longitudinal vibration GMT, thermal analysis was carried out. Following this, according to the heat transfer process of GMT, the TETN model was established and the corresponding model parameters were calculated. Finally, the accuracy of the TETN model for the temporal and spatial analysis of the transducer temperature are verified by simulation and experiment.
Giant magnetostrictive material (GMM), namely Terfenol-D, has the merits of large magnetostriction and high energy density. These unique characteristics can be exploited to enable the development of the giant magnetostrictive transducer (GMT) which can be used in a broad range of applications, such as under-water acoustic transducer, micro-motors, linear actuators and so on1,2.
Of particular concern is the possible overheating of underwater GMTs, which generate considerable heat due to their high dissipated power density when they are driven at full power and long excitation time3,4. In addition, the output characteristics of the GMT are closely related to temperature because of the large thermal expansion coefficient and its high sensitivity to external temperature5,6,7,8. Looking through the technical publications, the methods to face up the GMT thermal analysis can be divided into two main categories9: numerical and lumped parameter methods. The finite element method (FEM) is one of the most commonly used numerical analysis methods. Xie et al.10 used FEM to model heat source distribution of the giant magnetostrictive actuator and realized the temperature control of the actuator and the design of the cooling system. Zhao et al.11 created a coupled turbulent flow field and temperature field FEM simulation and constructed a GMM intelligent component temperature control device based on the FEM simulation results. However, FEM is very demanding in terms of model setup and computational time. For this reason, FEM is considered a valuable support for offline computations, typically during the transducer-design stage.
A lumped parameter method, often referred to as a thermal network model, is widely used in thermal dynamic analysis by virtue of its simple mathematical form and fast calculation speed12,13,14. This method has played an essential role in solving the thermal limitation problem of motors15,16,17. Mellor18 used an improved T-equivalent thermal circuit for the first time to simulate the heat transfer process of a motor. Verez et al.19 established a three-dimensional thermal network model for axial flux permanent magnet synchronous machines. Boglietti et al.20 proposed four thermal network models of different complexities for prediction of stator-winding short-term thermal transient. Finally, Wang et al.21 established the detailed equivalent thermal circuits for each component of the permanent magnet synchronous machine, and summarized the thermal resistance equations. The error can be controlled within 5% under rated conditions.
In the 1990s, the thermal network model began to be applied to low-frequency and high-power transducers. Dubus et al.22 built a thermal network model to describe heat transfer in double-ended longitudinal vibrator and class IV flextensional transducer at the steady state. Anjanappa et al.23 used the thermal network model to conduct a two-dimensional steady-state thermal analysis of a magnetostrictive mini-actuator. Zhu et al.24 established the steady-state equivalent thermal resistance and displacement calculation model of a GMT in order to study the relationship between the thermal deformation of Terfenol-D and the parameters of GMT.
Compared with that in the motor application, the GMT temperature estimation is more complicated. Most motor components considered at the same temperature have been usually simplified to a single node due to the excellent thermal and magnetic conductivity of the materials used13,19. Nevertheless, because of the poor thermal conductivity of GMM, the assumption of uniform temperature distribution is no longer valid. In addition, GMM has a very low permeability so that the heat generation resulted from magnetic losses is normally non-uniform along the GMM rod. Further-more, most of researches focused on steady-state modelling which is incapable of capturing temperature variances during the operation of GMTs.
To cope with the aforementioned three technical challenges, this paper takes the longitudinal vibration GMT as the research object, and accurately models different components of the transducer, especially the GMM rod. The complete transient equivalent thermal network (TETN) model of the GMT is established. A FEM model and an experimental platform were built to verify the accuracy and effectiveness of the TETN model for the temporal and spatial analysis of the temperature of the transducer.
The structure and geometry dimensions of longitudinal vibration GMT are shown in Fig. 1a and b, respectively.
Longitudinal vibration GMT: (a) configuration diagram, (b) dimension diagram.
The main components include the GMM rod, the excitation coil, the permanent magnets (PM), the magnetic yokes, the cover plates, the sleeve, and the disc spring. The excitation coil and PMs provide alternating and dc-biased magnetic fields for the GMM rod respectively. The magnetic yokes and shell composed of cover plates and sleeve are all made of soft iron, DT4, with a high magnetic conductivity. Together with the GMM rod and PMs, a closed magnetic circuit is formed. The output rod and the pressure plate are made of non-magnetic 304 stainless steel. With the disc spring, a stable prestress to the rod can be applied. When an alternating current is passed through the excitation coil, the GMM rod would vibrate accordingly.
In Fig. 2, the heat transfer process inside the GMT is illustrated. The GMM rod and excitation coil are the two main heat sources of the GMT. The coil transfers its heat to the shell by convection through the internal air and towards the cover plate by conduction. The GMM rod would generate magnetic losses under the action of the alternating magnetic field, and transfers the heat to the shell by convection through the internal air and to the PMs and magnetic yokes by conduction. The heat transferred to the shell is then dissipated outwards the environment by convection and radiation. When the heat generated is equal to the heat transferred, the temperature of each component of the GMT reaches at a steady state.
Heat transfer process in the longitudinal vibration GMT: (a) Heat flow diagram, (b) Main paths for heat transfer.
Except for the heat generated on the excitation coil and the GMM rod, all components within the closed magnetic circuit will also suffer from magnetic losses. Therefore, the PMs, magnetic yokes, cover plates and sleeve are all laminated to suppress the magnetic losses for the GMT.
The main steps of building a TETN model for thermal analysis of the GMT are as follows25: firstly, lump together components that have similar temperatures and represent each as a single node in the network; then, these nodes are coupled with appropriate heat transfer expressions, representing conduction and convection heat transfer between nodes. Meanwhile, the corresponding heat source and heat capacity of each component are connected in parallel between the node and zero voltage of common ground to build the equivalent heat network model. The next step is to calculate the thermal network parameters of each component in the model, including thermal resistances, heat capacities, and power losses. Finally, the TETN model is implemented in SPICE for simulation. And the temperature distribution in each component of the GMT and its variation in the time domain can be obtained.
For the convenience of modelling and calculation, it is necessary to simplify the thermal model and ignore the boundary conditions that have little impact on the results18,26. The TETN model proposed in this paper is established on the basis of the following assumptions:
Only consider the losses of rod and coil, and ignore the loss of other components.
The influence of temperature on the thermal parameters of different materials is ignored24,27.
Radiation heat transfer is ignored28. Only conduction and convective heat transfer are considered.
The contact thermal resistance between different components is ignored.
In GMTs that have randomly-wound windings, it is impossible or undesirable to model the position of each individual conductor. In the past, various modeling strategies have been developed to model the heat transfer and temperature distribution within a winding: (1) composite thermal conductivity; (2) direct equations bases on conductor geometries; (3) T-equivalent thermal circuit29.
The composite thermal conductivity and direct equations can be considered more accurate solutions than T-equivalent circuit but they depend on several factors, such as the materials, conductor geometries, and residual air quantity in windings, which are difficult to determine29. On the contrary, the T-equivalent thermal circuit, although as an approximate model, is more convenient30. It can be applied to the excitation coil in the longitudinal vibration GMT.
A general hollow cylindrical component used to represent the excitation coil and its T-equivalent thermal circuit that is derived from the solutions of the heat conduction equations are shown in Fig. 3. It is assumed that the heat flows inside excitation coil in the radial and axial directions are independent. The circumferential heat flow is ignored. In each T-equivalent circuit, two of the terminals represent the appropriate surface temperatures of the component, and the third terminal T6 represents the average temperature of the component. The losses P6 of the component are injected as a point source into the mean temperature node which are calculated in "Heat loss calculation of the excitation coil". In the case of transient modeling, the heat capacity C6, which is given by Eq. (1), is also added to the mean temperature node.
where cec, ρec and Vec represents the specific heat capacity, the density and the volume of the excitation coil.
The thermal resistances for T-equivalent thermal circuit of the excitation coil with the length lec, thermal conductivity λec, outer radius rec1, and inner radius rec2 are presented in Table 1.
Excitation coil and its T-equivalent thermal circuit: (a) General hollow cylindrical component, (b) Independent axial and radial T-equivalent thermal circuits.
T-equivalent circuit has also been proved accurate for other cylindrical heat sources13. As the main heat source of GMT, the temperature distribution of GMM rod is non-uniform due to its low thermal conductivity and the discrepancy is particularly pronounced along the axial of the rod. On the contrary, the radial non-uniformity can be ignored because the radial heat flow of GMM rod is far less than the radial heat flow31.
In order to accurately represent the axial discretization level of the rod and obtain the highest temperature, the GMM rod is represented by n nodes equally spaced in the axial direction, and the number of nodes n for GMM rod modeling must be equal to an odd number. The thermal circuit with n T-equivalent axial thermal circuits is presented in Fig. 4.
Thermal network model with n T-equivalent network circuit of GMM rod.
In order to determine the number of nodes n for GMM rod modeling, the FEM result is illustrated in Fig. 5 as a benchmark. The number of nodes n is tuned in the thermal circuit of GMM rod as shown in Fig. 4. Each node can be model as a T-equivalent circuit. Compared the result of FEM, it can be seen from Fig. 5 that one or three nodes cannot accurately reflect the temperature distribution of the GMM rod (a length of around 50 mm) in the GMT. When n is increased to five, the simulation results would be much improved and close to FEM. Further increase of n can also produce even better results but it will occur at the expense of increased computation time. Therefore, five nodes are selected in this paper to model the GMM rod.
Temperature distribution of the GMM rod in FEM and thermal network model with different complexity.
Based on the above comparative analysis, the accurate thermal circuit of GMM rod is presented in Fig. 6. T1 ~ T5 represent the mean temperatures of the five sections (Sections 1 ~ 5) of the rod. P1 ~ P5 represent the total thermal powers in different regions of the rod respectively, which are discussed in detail in the next chapter. C1 ~ C5 represents the heat capacities of different regions, which can be calculated by
where crod, ρrod and Vrod represents the specific heat capacity, the density and the volume of the GMM rod.
Equivalent thermal circuit with 5 nodes for the GMM rod in the GMT.
Applying the same method as for the excitation coil, the transfer thermal resistances of the GMM rod in Fig. 6 can be calculated by
where lrod, rrod and λrod represents the length, the radius and the thermal conductivity of the GMM rod.
For the longitudinal vibration GMT studied in this paper, the rest components and internal air can be modelled with single-node configurations.
These regions can be considered to consist of one or more cylinders. Pure conduction heat transfer couplings in the cylindrical component are determined from Fourier's Law of heat conduction as
where λnhs is the thermal conductivity of the material, lnhs is an axial length, and rnhs1 and rnhs2 are the outer and inner radius of the heat transfer component, respectively.
Equation (5) is used for calculation of the radial thermal resistances of these regions represented by RR4 to RR12 in Fig. 7. Meanwhile, Eq. (6) is used for calculation of the axial thermal resistances represented by RA15 to RA33 in Fig. 7.
Equivalent thermal network model of the longitudinal vibration GMT.
The heat capacity for the single-node thermal circuit of the aforementioned regions, including C7 to C15 in Fig. 7 can be given by
where ρnhs, cnhs and Vnhs represent the length, specific heat capacity density and volume, respectively.
Convective heat transfers across the internal air within the GMT as well as between the shell surface and the ambient is modelled with a single thermal conductive resistance as follows:
where A represents the contact surface and h is the heat transfer coefficient. Some typical h used in the thermal systems are listed in Table 232. According to Table 2, heat transfer coefficients of thermal resistances RH8–RH10 and RH14–RH18 in Fig. 7, which represented convection between the GMT and the ambient, take the constant value of 25 W/(m2 K). The rest heat transfer coefficients is set to 10 W/(m2 K).
According to the internal heat transfer process shown in Fig. 2, the complete TETN model of the transducer given in Fig. 7.
As can be seen in Fig. 7, the longitudinal vibration GMT was divided into 16 nodes, which were shown in red dots. The temperature nodes depicted in this model correspond to the average temperatures of their respective components. The ambient temperature is T0, the GMM rod temperature T1 ~ T5, the excitation coil temperature T6, the PMs temperature T7 and T8, the magnetic yokes T9 ~ T10, the shell temperature T11 ~ T12 and T14, the internal air temperature T13, and the output rod temperature is T15. Moreover, each node is connected to the thermal ground potential via C1 ~ C15 which respectively represent the thermal capacity of each region. P1 ~ P6 represent the total thermal powers of the GMM rod and excitation coil respectively. In addition, 54 thermal resistances are used to represent the conduction and convection heat transfer resistances between adjoining nodes, which have been calculated in the previous sections. Table 3 shows the different thermal properties of the materials which compose the transducer.
Accurate evaluation of the amount of losses and their distribution is of major importance in performing a reliable thermal modeling. The heat losses generated in the GMT can be divided into magnetic loss of GMM rod, joule loss of excitation coil, mechanical loss and additional loss. The additional loss and mechanical loss accounted for are relatively small and can be ignored36.
The AC resistance of the excitation coil includes: DC resistance Rdc and skin resistance Rs. For a sinusoidal alternating current with a Root Mean Square (RMS) value of I, the total thermal power P6 of the coil is given by35
The DC resistance Rdc can be calculated by
The resistance Rs due to the skin effect is given by
where f and N are the frequency of the excitation current and the number of turns. lCu and rCu represent the inner and outer radius of the coil, the length of the coil and the radius of the copper magnetic wire which is defined by its AWG (American Wire Gauge) number. ρCu is resistivity of its core. μCu is permeability of its core.
The actual magnetic field within the excitation coil, a solenoid, is non-uniform across the length direction of the rod. The discrepancy is particularly pronounced due to the low magnetic conductivity of GMM rod and PM. But it is longitudinally symmetric. The magnetic field distribution directly determines the distribution of magnetic loss of the GMM rod. Therefore, to reflect the actual loss distribution, three sections of the rod shown in Fig. 8 are taken for measurement.
Positions of induction coils on the GMM rod.
Magnetic loss can be obtained by measuring the dynamic hysteresis loop37. The dynamic hysteresis loops of three sections were measured based on the experimental platform shown in Fig. 11. Under the condition of the GMM rod temperature stable below 50 °C, a programmable ac power supply (Chroma 61512) drives the excitation coil over a range of frequencies with a test current to produce a magnetic field and the resulting flux density is derived by integrating the voltage induced in the induction coils attached to the GMM rod as shown in Fig. 8. Raw data was downloaded from the memory hicorder (Daily MR8875-30) and processed in MATLAB software to derive the measured dynamic hysteresis loops shown in Fig. 9.
Measured dynamic hysteresis loops: (a) Section 1/5: Bm = 0.044735 T, (b) Section 1/5: fm = 1000 Hz; (c) Section 2/4: Bm = 0.05955 T, (d) Section 2/4: fm = 1000 Hz, (e) Section 3: Bm = 0.07228 T, (f) Section 3: fm = 1000 Hz.
According to literature37, the total magnetic loss per unit volume Pv of GMM rod can be calculated from:
where ABH is the measured area within the B-H curve at the magnetic field frequency fm which is equal to the excitation current frequency f.
Based on the Bertotti loss separation method38, magnetic loss per unit mass of GMM rod Pm can be expressed as the sum of hysteresis loss Ph, eddy current loss Pe and abnormal loss Pa (13):
From the perspective of engineering analysis38, abnormal loss and eddy current loss can be combined into one term called total eddy current loss. Therefore, the loss calculation formula can be simplified to:
In Eqs. (13)–(14), Bm is the magnetic density amplitude of the excitation magnetic field. kh and kc are the hysteresis loss coefficient and the total eddy current loss coefficient.
According to literature39, based on simplified loss separation formula and loss test data, polynomial curve fitting method is adopted to mathematically obtain the hysteresis loss coefficient and total eddy current loss coefficient, which are listed as (12) and (13):
where a0, a1, a2, b0, b1, b2 and b3 are the relevant parameters of material loss. According to the fitted experimental data, the seven loss-related parameters in different sections were obtained for different sections (Fig. 6) as shown in Table 4.
Table 5 shows the magnetic loss values P1 ~ P5 in different sections of the GMM rod by the fitted loss separation formula at different current levels.
It can be seen from Table 4 that the magnetic loss at the GMM rod ends are far less than that at the center, which proves the obvious non-uniformity of magnetic loss along the axial direction of the rod. Meanwhile, the non-uniformity is continuously amplified with the increase of the excitation current. The non-uniform loss distribution of GMM rod significantly affects the accuracy of whatever thermal analysis approach, especially for low frequency, high power GMT.
To better verify the accuracy of the TETN model for the temperature distribution of the GMM rod, the longitudinal vibration GMT was modeled by employing COMSOL Multiphysics software shown in Fig. 10. A half symmetry sector with symmetry boundary conditions and a volume free meshing generated by only pyramid (tetrahedral) elements type was used. Complete mesh consists of 108,924 domain elements, 23,976 boundary elements, and 2448 edge elements completely.
Finite element model of longitudinal vibration GMT.
The GMM rod temperature T1 ~ T5 obtained from the FEM simulation and the TETN model are all compared in Fig. 11 under I = 3A and f = 1000 Hz.
Comparison of the GMM rod temperature at different positions obtained from the FEM simulation and the TETN model.
As Fig. 11 shows, the temperature is lowest at node 5. The TETN model produces a smaller temperature than FEM with an error of around 0.89 °C at the steady state. With the increased of node temperature, the differences between the TETN model and FEM increased to 2.31 °C and 2.93 °C respectively at node 4 and node 3. Figure 11 shows a good agreement between the simulation results of the TETN model and FEM with a small error of below 2%, which indicates that the proposed model achieves an accurate simulation result for GMM rod temperature distribution.
IN order to validate the effectiveness and accuracy of the proposed model, a temperature rise experimental platform has been built as shown in Fig. 12a. A programmable ac power supply (Chroma61512) is chosen to supply and control excitation current of the longitudinal vibration GMT. K-type temperature sensors are used for real-time collection of the temperature at different positions. An oscilloscope (Tektronix MDO34) is used for monitoring voltage and current, while a memory hicorder (Daily mr8875-30) for data storage. The computer gets data from the memory hicorder, and is used to process data.
Temperature rise experimental platform for longitudinal vibration GMT: (a) Experimental platform, (b) Selected test positions.
Starting with the longitudinal vibration GMT at the ambient temperature, the test is performed for a time length of 20 min to avoid the GMM rod temperature reaching half of the Curie point, which would affect the reliable operation of the GMT. For comparison reasons, the central surface of the rod, the inner wall of excitation coil and shell temperatures are recorded during the experimental investigations.
To demonstrate the performance of the TETN model for temperature estimation, the temperatures of the central surface of the rod, the inner wall of the excitation coil and shell were measured when I range from 1.5 to 3 A, as show in Fig. 12b.
Final results of the proposed model, FEM and experimental measurement at various positions are presented in Table 6. The maximum final temperature differences seen between the results of TETN simulations and the measured data is 3.46 °C in the central surface of GMM rod, 2.03 °C in the inner wall of excitation coil and 1.44 °C in the inner wall of shell respectively.
Figure 13 shows a time-based comparison between the measured and simulated results at three selected test positions. The simulated results for the GMM rod are comparable to the measured results with a slight deviation within 1.5 °C when the excitation current is 1.5 A and 2 A in Fig. 13a. With the increase of temperature, the differences between the measured and simulated results occurring during the initial transient period increase to 5.01 °C and 15.92 °C at I = 2.5 A and 3 A, which probably is attributed to the less accurate heat capacity value for GMM rod. Furthermore, the power losses are not constant at high temperatures in reality, which are assumed to be unchanged as measured at room temperature39.
Comparison of measured values and model results of temperature rise at different positions of GMT: (a) The central surface of GMM rod, (b) The inner wall of excitation coil, (c) The inner wall of sleeve.
As shown in Fig. 13b, the proposed model is more accurate in estimation of the excitation coil temperature. The maximum errors of the TETN model and experiment are within 3 °C. However, it is apparent that the temperature rise trend for the coil for FEM is quite different from the experiment. The main reason probably is that the excitation coil transfers its heat by convection through the internal air. Nevertheless, COMSOL cannot accurately describe the heat flux of internal air. In Fig. 13c, there is a good agreement between the measured and calculated results of the temperature of the inner wall of the shell. Whereas, with the increase of the excitation current, the measured temperature increases faster than the calculated temperature as the surface radiation of the shell which is assumed in the proposed model to be ignored becomes increasingly important in reality.
To sum up, the proposed thermal modeling method can be successfully applied to the low frequency, high power GMT. Optimization on the TETN model should be required to account for the radial heat transfer if the radial loss distribution of the GMM rod become very pronounced at higher operating frequency due to the increased eddy current effect.
A TETN model has been established and applied to estimate the temperature distribution of a longitudinal vibration GMT in this paper. In particular, the distinctiveness of GMM rod being also as a heat source, and additionally the influence of temperature and heat generation distribution of the GMM rod are fully discussed and considered. In this paper, the complete procedure for the equivalent thermal circuits of each part of the GMT was reported and the corresponding model parameters were calculated in detail. The accuracy of this model in transducer temperature estimation was verified through FEM simulation and experiments. Furthermore, the error analysis at all selected test positions is discussed, which should shed light on the further improvement of the TETN model.
The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.
Rong, C. et al. Dynamic modeling and analysis of stack giant magnetostrictive actuator. Sens. Actuators A. 276, 205–218 (2018).
Article CAS Google Scholar
Yadav, S. & Mehta, R. K. Modelling of magnetostrictive vibration and acoustics in converter transformer. IET Electr. Power Appl. 15, 332–347. https://doi.org/10.1049/elp2.12025 (2021).
Article Google Scholar
Xue, G. et al. Simulation studies on the boot shape injection of a giant magnetostrictive injector. Sci. Rep. 11, 22999. https://doi.org/10.1038/s41598-021-02529-z (2021).
Article ADS CAS PubMed PubMed Central Google Scholar
Butler, S. C. & Montgomery, R. E. A Thermal analysis of high-drive ring transducer elements. Naval Undersea Warfare Center Div Newport Ri (2005).
Blottman, J. B. et al. Thermal design of high-power active transducers with the atila finite element code. Proc. Inst. Acoust. 27(1), 87–94 (2005).
Google Scholar
Debus, J. C. Thermal Analysis in Piezoelectric and Magnetostrictive Materials Using ATILA Applications of ATILA FEM Software to Smart Materials 230–282 (Woodhead Publishing, 2013).
Google Scholar
Zhao, Z. & Sui, X. Temperature compensation design and experiment for a giant magnetostrictive actuator. Sci. Rep. 11, 251. https://doi.org/10.1038/s41598-020-80460-5 (2021).
Article CAS PubMed PubMed Central Google Scholar
Nersessian, N., Or, S. W. & Carman, G. P. Magneto-thermo-mechanical characterization of 1–3 type polymer-bonded Terfenol-D composites. J. Magn. Magn. Mater. 263(1–2), 101–112 (2003).
Article ADS CAS Google Scholar
Dubus, B. Thermal limit analysis of low-frequency high power sonar projectors. in 1st European Conference on Underwater Acoustics (1992).
Xie, T., Wang, C., Yu, C., Xu, B. & Shi, R. The temperature rise characteristics analysis and experiment of GMA. AIP Adv. 10(10), 105126 (2020).
Article ADS Google Scholar
Zhao, Z. & Sui, X. Temperature compensation design and experiment for a giant magnetostrictive actuator. Sci. Rep. 11(1), 1–14 (2021).
Google Scholar
Vahedi, P., Ganji, B. & Afjei, E. Lumped thermal model for the multi-layer switched reluctance motor. IET Electr. Power Appl. 14, 1873–1885. https://doi.org/10.1049/iet-epa.2019.1025 (2020).
Article Google Scholar
Rostami, N. et al. Lumped-parameter thermal model for axial flux permanent magnet machines. IEEE Trans. Magn. 49(3), 1178–1184 (2012).
Article ADS Google Scholar
Gan, Y., Wang, J., Liang, J., Huang, Z. & Hu, M. Development of thermal equivalent circuit model of heat pipe-based thermal management system for a battery module with cylindrical cells. Appl. Therm. Eng. 164, 114523 (2020).
Article Google Scholar
Kang, M., Shi, T., Guo, L., Gu, X. & Xia, C. Thermal analysis of the cooling system with the circulation between rotor holes of enclosed PMSMs based on modified models. Appl. Therm. Eng. 1, 118054 (2022).
Article Google Scholar
Cavazzuti, M., Gaspari, G., Pasquale, S. & Stalio, E. Thermal management of a Formula E electric motor: Analysis and optimization. Appl. Therm. Eng. 157, 113733 (2019).
Article Google Scholar
Liu, F., Hu, J., Li, Y. & Wang, Q. Improved thermal model of forced air-cooled motors considering heat transfer in wire-wound winding and end region. IET Electr. Power Appl. 14, 943–950. https://doi.org/10.1049/iet-epa.2019.0780 (2020).
Article Google Scholar
Mellor, P. H., Roberts, D. & Turner, D. R. Lumped parameter thermal model for electrical machines of TEFC design. IEE Proc. B Electr. Power Appl. 138(5), 205–218 (1991).
Article Google Scholar
Verez, G., Tiegna, H., Barakat, G. & Hoblos, G. Analytical thermal modelling of axial flux permanent magnet synchronous machines. in Proc. 2012 20th Int. Conf. Electr. Mach. ICEM, 2799–2805 (2012).
Boglietti, A., Cavagnino, A. & Staton, D. Determination of critical parameters in electrical machine thermal models. IEEE Trans. Ind. Appl. 44(4), 1150–1159 (2008).
Article Google Scholar
Wang, W. B. Lumped-Parameter Thermal Model Analysis for PMSM 16–33 (Zhejiang University, 2014).
Google Scholar
Dubus, B. An analytical evaluation of the heating of low-frequency sonar projectors. J. Acoust. Soc. Am. 95(4), 1983–1990 (1994).
Article ADS Google Scholar
Anjanappa, M. & Bi, J. A theoretical and experimental study of magnetostrictive mini-actuators. Smart Mater. Struct. 3(2), 83–91 (1994).
Article ADS Google Scholar
Zhu, Y. & Ji, L. Theoretical and experimental investigations of the temperature and thermal deformation of a giant magnetostrictive actuator. Sens. Actuators A. 218, 167–178 (2014).
Article CAS Google Scholar
Boglietti, A. et al. Evolution and modern approaches for thermal analysis of electrical machines. IEEE Trans. Ind. Electron. 56(3), 871–882 (2009).
Article Google Scholar
Xu, Y., Ai, M. & Yang, Y. Heat transfer characteristic research based on thermal network method in submersible motor. Int. Trans. Electr. Energy Syst. 28(3), e2507 (2018).
Article Google Scholar
Debus, J. C., Blottman, J. III. & Butler, S. Thermal behavior of high-power active devices with the ATILA (analysis of transducers by integration of LAplace equations) finite-element code. J. Acoust. Soc. Am. 120(5), 3274–3274 (2006).
Article ADS Google Scholar
De-xing, Z., Weifang, C. & Miaomiao, L. An optimized thermal network model to estimate thermal performances on a pair of angular contact ball bearings under oil-air lubrication. Appl. Therm. Eng. 131, 328–339 (2018).
Article Google Scholar
Staton, D., Boglietti, A. & Cavagnino, A. Solving the more difficult aspects of electric motor thermal analysis in small and medium size industrial induction motors. IEEE Trans. Energy Convers. 20(3), 620–628 (2005).
Article ADS Google Scholar
Perez, I. J. & Kassakian, J. G. A stationary thermal model for smooth air-gap rotating electric machines. Electr. Mach. Power Syst. 3(3–4), 285–303 (1979).
Article Google Scholar
El-Refaie, A. M., Harris, N. C., Jahns, T. M. & Rahman, K. M. Thermal analysis of multibarrier interior PM synchronous machine using lumped parameter model. IEEE Trans. Energy Convers. 19(2), 303–309 (2004).
Article ADS Google Scholar
Bahman, A. S., Ma, K. & Blaabjerg, F. A lumped thermal model including thermal coupling and thermal bound- ary conditions for high-power IGBT modules. IEEE Trans. Power Electron. 33(3), 2518–2530 (2017).
Article ADS Google Scholar
Roy, P. Thermal Modeling of Permanent Magnet Synchronous Motors for Electric Vehicle Application (Doctoral dissertation, University of Windsor). (2020).
Jung, Y. G., Choi, S. C., Oh, C. S. & Paik, U. G. Residual stress and thermal properties of zirconia/metal (nickel, stainless steel 304) functionally graded materials fabricated by hot pressing. J. Mater. Sci. 32(14), 3841–3850 (1997).
Article ADS CAS Google Scholar
Angara, R. High Frequency High Amplitude Magnetic Field Driving System for Magnetostrictive Actuators (University of Maryland, 2009).
Google Scholar
Grunwald, A. & Olabi, A. G. Design of a magnetostrictive (MS) actuator. Sens. Actuators A Phys. 144(1), 161–175 (2008).
Article CAS Google Scholar
Du, R. & Robertson, P. Modelling of dynamic magnetic hysteresis loops and power losses in laminated steel. in Proc. UKSim-AMSS 17th Int. Conf. Comput. Model. Simulation, UKSim 2015, 432–437 (2016).
Guo, P. et al. Variable coefficient magnetic energy loss calculating model for magnetostrictive materials considering compressive stress. AIP Adv. 11(3), 035227 (2021).
Article ADS Google Scholar
Huang, W., Xia, Z. & Guo, P. High frequency characteristic test and loss calculation of TbDyFe alloy under variable temperature. IEEE Trans. Magn. (2021).
Download references
National Electric Power Conversion and Control Engineering Technology Research Center (Hunan University), Changsha, Hunan, China
Zhihe Zhang, Xin Yang & Yukai Chen
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
Z.Z. and Y.C.: data analysis and simulation; X.Y.: conceived the manuscript; Z.Z.: wrote original manuscript and drew the images in the manuscript; X.Y. and Z.C.: revised manuscript and checked all data.
Correspondence to Xin Yang.
The authors declare no competing interests.
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Reprints and Permissions
Zhang, Z., Yang, X. & Chen, Y. Research on equivalent thermal network modeling for rare-earth giant magnetostrictive transducer. Sci Rep 12, 18088 (2022). https://doi.org/10.1038/s41598-022-22959-7
Download citation
Received: 31 May 2022
Accepted: 21 October 2022
Published: 27 October 2022
DOI: https://doi.org/10.1038/s41598-022-22959-7
Anyone you share the following link with will be able to read this content:
Sorry, a shareable link is not currently available for this article.
Provided by the Springer Nature SharedIt content-sharing initiative
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.